The following products have passed the tests obtaining a declaration of conformity by a qualified technician, in reference to the regulations in force

THE FOLLOWING PRODUCTS HAVE PASSED THE TESTS OBTAINING DECLARATION OF CONFORMITY ACCORDING TO THE FLORIDA BUILDING CODE 1618.4.6
Constrained on one side only, without handrail.
Continuous and/or punctual constraint (linear with or without continuity).

 
DP psf DP x 2 psf H balustrade with walking surface ft Recommended product Glass type Impacts
+/- 90 +/- 180 3,6 ft Garda SP - AP 200 3/8” T / 0,030”
SGP Interlayer /
3/8” T
SM Impact
(TAS 201-94)
+/- 120 +/- 240 3,6 ft Garda SP-AP 300 1/2” T / 0,060”
SGP Interlayer /
1/2” T
LM Impact
(TAS 201-94)

MIAMI DADE IMPACT CERTIFICATION TESTS (IMPACT TEST ZONE 4 – FLORIDA)

GARDA SP – AP 200 WITH 3/8” TEMPERED GLASS / 0,060” SGP Interlayer / 3/8” TEMPERED GLASS CERTIFIED FOR:


– DESIGN LOAD (TAS 202-94) +/- 90 PSF
– SMI IMPACT (TAS 201-94)
– BALL IMPACT (ANSI Z97.1)


GARDA SP – AP 300 WITH 1/2” TEMPERED GLASS / 0,030” SGP Interlayer / 1/2” TEMPERED GLASS CERTIFIED FOR:
– DESIGN LOAD (TAS 202-94) +/- 120 PSF
– LMI IMPACT (TAS 201-94)
– BALL IMPACT (ANSI Z97.1)

GROUP 1, TYPE A
Constrained on one side only, without a handrail.
Continuous and/or punctual constraint (linear with or without continuity).

Group 1 - type A
SLS* kN/m ULS kN/m H balustrade with walking surface mm Recommended product Minimum glass type Recommended type of glass
1,0 1,5 1100 Garda SP-AP 100
SP - AP - FS 200
SP-AP special 200
FS-FS special 200
8/8 T+I PVB 8/8 T+I PVB
1,0 1,5 650 Garda Mini 8/8 T+I PVB 8/8 T+I PVB
2,0 3,0 1100 SP - AP - FS 200
SP-AP special 200
FS-FS special 200
8/8 T+I PVB 10/10 T+I PVB
8/8 T+T CLASS 2
2,0 3,0 650 Garda Mini 8/8 T+I PVB 8/8 T+I PVB
3,0 4,5 1100 Garda SP-AP 300
Garda FS 300
10/10 T+T PLASTIC CLASS 2 10/10 T+T
CLASS 2

GROUP 2, TYPE D
Constrained on one side only, with handrail of distribution of the loads between adjoining slabs.
Continuous and/or punctual constraint (linear with or without continuity).

Group 2 - type D
SLS* kN/m ULS kN/m H balustrade with walking surface mm Recommended product Minimum glass type Recommended type of glass
1,0 1,5 1100 Garda SP-AP 100
SP - AP - FS 200
Fs-fs special 200
Garda Mini
8/8 T+I PVB 8/8 T+I PVB
1,0 1,5 650 Garda Mini 8/8 T+I PVB 8/8 T+I PVB
2,0 3,0 1100 Garda SP-AP 100
SP - AP - FS 200
SP- AP special 200
FS-FS special 200
8/8 T+I PVB 10/10 T+I PVB
8/8 T+T CLASS 2
2,0 3,0 650 Garda Mini 8/8 T+I PVB 8/8 T+I PVB
3,0 4,5 1100 Garda SP-AP 300
Garda FS 300
10/10 T+I PVB 10/10 T+T
CLASS 2

Safety

The main standards to be met**

NTC 2018 * UPDATING OF TECHNICAL STANDARDS FOR CONSTRUCTIONS

Italian Ministerial Decree of 17 January 2018
3.1.II OVERLOADING – Provides the required resistances for the elements to protect against falling from a height.*

UNI 7697: 2015 *

February 2015
UNI safety standard for the use of flat glass in construction. Provides information on the types of glass to be used for balustrades. *

UNI 11678:2017 *

15 May 2017
“Glass for the building industry – Glass cladding elements with fall protection function – Resistance to linear static load and dynamic load – Test Methods”

UNI standard
The standard defines the test methods to determine the behaviour of linearly distributed static loads and dynamic loads of glass cladding elements with fall protection function.

DM 236 *

14 June 1989
Technical requirements necessary to ensure accessibility, adaptability and visitability of private buildings and public housing subsidised and facilitated, for the purpose of overcoming and eliminating architectural barriers.
Provides the minimum height of the railings and balustrades in addition to the indications on the necessity and types of handrail.

* In force at the time of printing, check any changes, updates or the presence of new regulations
** Without prejudice to any local regulations in force in the territory where the final customer is located.

2018 NTC EXTRACT – ITALIAN TECHNICAL STANDARDS

Overloading values for different use categories of constructions

Category A
Environments for residential use kN/m
Areas for domestic and residential activities; this category includes the rooms of houses and related services, hotels (excluding areas subject to crowding), hospital rooms 1,0
Community staircases, balconies, walkways 2,0
Category B
Offices kN/m
Cat. B1 Offices not open to the public (excluding areas subject to crowding) 1,0
Cat. B2 Offices open to the public (excluding areas subject to crowding) 1,0
Community staircases, balconies, walkways 2,0
Category C
Environments susceptible to crowding kN/m
Cat. C1 Areas with tables, such as schools, cafes, restaurants, banquet rooms, reading and reception (excluding areas subject to crowding) 1,0
Cat. C2 Fixed seating areas such as churches, theatres, cinemas, conference and waiting rooms, university classrooms and lecture halls 2,0
Cat. C3 Spaces without obstacles to the movement of people, such as museums, exhibition halls, access areas to offices, hotels and hospitals, to lobbies of railway stations 3,0
Cat. C4 Areas with possible physical activities such as ballrooms, gyms, stages 3,0
Cat. C5 Areas that are susceptible to large crowds, such as public event buildings, concert halls, sports arenas and related grandstands, staircases and railway platforms 3,0
Community staircases, balconies, walkways According to the category of use served ≥ 2.0
Category D
Environments for commercial use kN/m
Cat. D1 Shops 2,0
Cat. D2 Shopping centres, markets, department stores 2,0
Community staircases, balconies, walkways According to the category of use served
Category E
Areas for warehousing and commercial use and industrial use kN/m
Cat. E1 Areas for the storage of goods and related areas of access, such as libraries, archives, warehouses, depots, manufacturing laboratories 1,0*
Cat. E2 Environments for industrial use To be assessed case-by-case
Category F-G
Depots and areas for vehicle traffic (excluding bridges) <kN/m
Cat. F Depots, areas for traffic, parking and stopover of light vehicles (weight at full load up to 30 kN) 1,0**
Cat. G Areas for traffic and car parks of medium-size vehicles (full-load weight between 30kN and 160 kN), such as access ramps, cargo loading and unloading areas 1,0**
Category H-I-K
Roofing kN/m
Cat. H Roofing accessible for maintenance and repair only 1,0
Cat. I Roofing subject to pedestrian traffic of environments in the category of use between A and D According to categories
Cat. K Roofing for special uses such as installations, heliports To be assessed case-by-case

* It does not include the horizontal actions possibly exerted by the materials stored.
** Only for railings or partitions in pedestrian areas. The actions on the barriers exerted by the vehicles must be assessed on a case-by-case basis.

Certifications

High safety standards
All products of the Garda system are tested in accredited laboratories of the Ministry of Public Works and have passed tests on dynamic and static loads up to 4.5 kN/m (up to 300 kg/m).

Istituto Giordano
In addition, the balustrades have passed tests, obtaining a declaration of conformity in compliance with the current technical standards for constructions.

ABP Test
The Garda System complies with the German standard rules DIN 18008, as it passed the required tests and obtained an Allgemeines Bauaufsichtliches Prufzeugnis.
The ABP is the general construction test certificate issued by institutions accredited by the German authorities in this field. Only products that obtain this certification can be distributed on the German market.

Florida Building Code 1618.4.6
Garda SP-AP 200 and Garda SP-AP 300 have passed Miami-Dade Impact tests obtaining declaration of conformity according to the Florida Building Code 1618.4.6 for Wind Zone 4 (High Velocity Hurricane Zone).

Test Miami Dade Impact